Chapter 5: Local Management
5-28
2E42-27/2E42-27R/2E43-27/2E43-27R User’s Guide
3.
Use the arrow keys to highlight YES. Press ENTER.
4.
If you ENABLED the port, proceed to step 5. If you DISABLED the 
port, use the arrow keys to highlight SAVE at the bottom of the screen, 
then press ENTER.
5.
When the message “SAVED OK” appears, the edits you made are 
saved. 
5.7.10.1 Changing the Com Port Application
After enabling the COM port as described in 
, one of the 
applications supported by the COM port (LM or UPS) can be selected. 
The default application is LM.
To change the COM port application: 
1.
Use the arrows keys to highlight the Application field.
2.
Use the SPACE bar or BACKSPACE to step through the available 
settings until the operation you require appears. 
available settings and their corresponding applications. 
3.
Press ENTER to accept the application.
4.
Use the arrow keys to highlight SAVE at the bottom of the screen, then 
press the ENTER key. The message “SAVED OK” displays, 
indicating that the edits are saved.
NOTE
Exiting without saving causes the message “NOT SAVED -- 
PRESS SAVE TO KEEP CHANGES” to appear. Exiting without 
saving causes all edits to be lost.
Table 5-3
COM Port Application Settings
Setting
Application
[LM]
Local Management Session
[UPS]
APC Power Supply SNMP Proxy