8-12
Time Protocols     
SNTP: Viewing, Selecting, and Configuring
Ti
m
e
 Pr
ot
o
c
o
ls
Changing the SNTP Poll Interval. 
This command lets you specify how 
long the switch waits between time polling intervals. The default is 720 
seconds and the range is 30 to 720 seconds. (This parameter is separate from 
the poll interval parameter used for Timep operation.)
Syntax:
sntp poll-interval <30 . . 720>
For example, to change the poll interval to 300 seconds:
HP4108(config)# sntp poll-interval 300
Disabling Time Synchronization Without Changing the SNTP 
Configuration. 
The recommended method for disabling time synchroniza-
tion is to use the 
timesync
 command. This halts time synchronization without 
changing your SNTP configuration.
Syntax:
no timesync
For example, suppose SNTP is running as the switch’s time synchronization 
protocol, with 
Broadcast
 as the SNTP mode and the factory-default polling 
interval. You would halt time synchronization with this command:
HP4108(config)# no timesync
If you then viewed the SNTP configuration, you would see the following:
Figure 8-10.  Example of SNTP with Time Sychronization Disabled
Disabling the SNTP Mode. 
If you want to prevent SNTP from being used 
even if selected by 
timesync
 (or the Menu interface’s 
Time Sync Method
 param-
eter), configure the SNTP mode as disabled.
Syntax:
no sntp  Disables SNTP by changing the SNTP mode configura-
tion to 
Disabled
.
For example, if the switch is running SNTP in Unicast mode with an SNTP 
server at 10.28.227.141 and a server version of 3 (the default), 
no sntp
 changes 
the SNTP configuration as shown below, and disables time synchronization 
on the switch.