rmon hc-alarm
Set an alarm on any MIB object.
S4820T
Syntax
rmon hc-alarm number variable interval {delta | absolute} 
rising-threshold value event-number falling-threshold value 
event-number
 [owner string]
To disable the alarm, use the no rmon hc-alarm number command.
Parameters
number
Enter the alarm integer number from 1 to 65535. The value 
must be unique in the RMON alarm table.
variable
The MIB object to monitor. The variable must be in the 
SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object 
type must be a 64-bit integer.
interval
Time, in seconds, the alarm monitors the MIB variables; this 
is the alarmSampleType in the RMON alarm table. The range 
is from 5 to 3600 seconds.
delta
Enter the keyword delta to test the change between MIB 
variables. This is the alarmSampleType in the RMON alarm 
table.