(1) Connecting to a 100-pin LCC Socket
To connect the M30800T-PTC (included) to the 100-pin LCC socket (IC61-1004-051 by Yamaichi
Electronics Co., Ltd.) on the target system, following the procedure below.
Electronics Co., Ltd.) on the target system, following the procedure below.
(1) Attach the CN2 side of the M30800T-PTC to the tip (CN2 side) of the pitch converter board
connected to the emulation pod probe.
(2) Attach the M30800T-PTC to the 100-pin LCC socket.
Figure 3.13 Connecting to a 100-pin LCC socket
CAUTION
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulation pod.
• The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
• The IC61-1004-51 included with this product is guaranteed for only 20 insertion/
removal iterations.
• For purchasing the IC61-1004-51 or for technical information, contact Yamaichi
Electronics Co., Ltd. (http://www.yamaichi.co.jp/e/index.shtml)