2.9.3 Connecting to a 100-pin 0.65mm pitch Foot Pattern (Part 2) 
Figure 2.10 shows how to connect the emulation probe to a 100-pin 0.65mm pitch foot pattern on the user system with the 
M3T-DIRECT100S (not included), and here following is its procedure. For details on the M3T-100LCC-DMS and M3T-
DIRECT100S, refer to each user's manual. 
 
(1)  Attach the M3T-DIRECT100S to the user system. 
(2)  Attach the M3T-100LCC-DMS to the M3T-DIRECT100S. 
(3)  Attach the M30800T-PTC to the M30850T2-EPB. 
(4)  Attach the M30800T-PTC to the M3T-100LCC-DMS. 
 
 
M3T-100LCC-DMS
(not included)
M3T-FLX160-EPB
M30850T2-EPB
CN2 side
(3)
(4)
M30800T-PTC
(2)
(1)
100-pin 0.65mm pitch
(PRQP0100JB-A) foot pattern
No.1  pin
User system
M3T-DIRECT100S 
(not included)
 
 
Figure 2.10 Connecting to a 100-pin 0.65mm pitch foot pattern (2/3) 
 
  CAUTION 
Notes on Connecting the User System: 
 
z Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator. 
z The small connectors of the M3T-100LCC-DMS and M3T-DIRECT100S are guaranteed for only 20 
insertion/removal iterations. 
z The small connectors of the M30850T2-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal 
iterations. 
 
 
 