Renesas M30850T2-EPB Manual Do Utilizador

Página de 98
M30850T2-EPB User’s Manual 
2. Setup 
REJ10J1005-0200  Rev.2.00  April 1, 2007 
 
2.10.2 Selecting Clock Supply 
You can choose a clock supplied to the evaluation MCU by the Emulator tab in the Init dialog box of the emulator debugger. 
Table 2.4 lists the factory-settings of each clock supply. 
 
Table 2.4 Clock supply to the MCU and default settings 
Clock 
Display of emulator debugger
Description 
Default setting 
Internal 
Internal oscillator circuit 
(OSC-3 or OSC-2) 
Yes 
External 
Oscillator of user system 
Main X
IN
-X
OUT
 
Generated 
Internal generator circuit 
(1.0 to 32.0 MHz) 
Internal 
Internal oscillator circuit 
(32.768 kHz) 
Sub X
CIN
-X
COUT
 
External 
Oscillator of user system 
Yes 
 
 
IMPORTANT 
Notes on Changing the Clock Supply: 
 
z The clock supply can be set by the Init dialog box when starting up the emulator debugger or inputting CLK 
command on the script window. 
z For XCIN-XCOUT, it is necessary to set switches in the emulator. For details, refer to "2.10.1 Setting Switches 
of Emulation Probe" (page 38). 
 
 
(1)  Using an Internal Oscillator Circuit Board 
1)  Kinds of Oscillator Circuit Boards 
 
The PC7501 comes with an oscillator circuit board OSC-3 (30 MHz). And an oscillator circuit board OSC-3 (32 MHz) 
and an oscillator circuit board OSC-2 (bare board) are included with this product. If you use the internal oscillator 
circuit board OSC-3 (32 MHz) or OSC-2 of the PC7501 as a main clock, choose "Internal" in the emulator debugger 
after replacing oscillator circuit boards to change a clock supplied to an MCU. 
 
 
Page 40 of 98