Renesas M301N2T-PRB Manual Do Utilizador

Página de 48
M301N2T-PRB User’s Manual 
1. Outline   
REJ10J0037-0100 Rev.1.00 Mar.16, 2005 
 
Page 15 of 48 
 
 
(2) Target Status LEDs 
The target status LEDs indicate the target MCU's operating status and power supply. Table 1.4 lists the definition of each target 
status LED. 
 
Table 1.4 Definitions of the target status LEDs 
Name Status 
Meaning 
ON 
Power is supplied to the target MCU. 
POWER 
OFF 
Power is not supplied to the target MCU. 
ON 
Target MCU clock is supplied. 
CLOCK 
OFF 
Target MCU clock is not supplied. 
ON 
Target MCU is being reset, or reset signal of the user system is held low. 
RESET 
OFF 
Target MCU is not being reset. 
ON 
User program is being executed. 
RUN 
OFF 
User program has been halted. 
ON 
Target MCU internal clock is not oscillating. 
HALT 
OFF 
Target MCU internal clock is oscillating. 
 
 
 
IMPORTANT
 
Caution for Target Status POWER LED: 
 
 
If your MCU has two or more power supply terminals (VCC), you need to supply power to all the 
terminals.