Nortel Networks 10BASE-T Manual Do Utilizador

Página de 330
Using the BayStack 410-24T 10BASE-T Switch
3-60
309985-C Rev 00
MultiLink Trunk Configuration Screen
The MultiLink Trunk Configuration screen (
) allows you to configure 
up to six trunks in a standalone switch or stack. In a stack configuration, trunk 
members can be distributed between any of the units within the same stack 
configuration.
Any mix of up to eight BayStack 410-24T switches and BayStack 450 switches 
can be stacked to provide a total of 224 ports (when all MDA slots are configured 
with the maximum port availability).
 shows six trunks in a stack configuration:
Trunk 1 has four trunk members in unit 3.
Trunks 2, 3, 4, and 5 each have two trunk members in individual units.
Trunk 6 has four trunk members distributed into four separate units of the 
stack.
When the trunks are enabled, the trunk members take on default settings necessary 
for correct operation of the MultiLink Trunking feature. These default settings can 
affect the correct operation of your configured network. If you disable a trunk, you 
may need to reconfigure the specific trunk members’ switch ports to return to the 
previous switch configuration. See “
” on 
 for more 
information.
Choose Trunk Configuration (or press t) from the MultiLink Trunk Configuration 
Menu screen to open the MultiLink Trunk Configuration screen.