Nortel Networks 10BASE-T Manual Do Utilizador

Página de 330
Using the BayStack 410-24T 10BASE-T Switch
1-20
309985-C Rev 00
You can attach a probe device (such as a Nortel Networks StackProbe, or 
equivalent) to the designated monitor port.
For more information about the port mirroring feature, see “
 on 
BootP Automatic IP Configuration/MAC Address
The BayStack 410-24T switch has a unique 48-bit hardware address, or MAC 
address, that is printed on a label on the back panel. You use this MAC address 
when you configure the network BootP server to recognize the BayStack 410-24T 
switch BootP requests. A properly configured BootP server enables the switch to 
automatically learn its assigned IP address, subnet mask, IP address of the default 
router (default gateway), and software image file name.
When the switch is participating in a stack configuration, a Stack MAC address is 
assigned automatically during the stack initialization. The base unit’s MAC 
address, with an offset, is used for the Stack MAC address.
For example, if the base unit’s MAC address is:
00-00-82-99-44-00
and the offset is:
1F
then the Stack MAC address becomes:
00-00-82-99-44-1F
If another unit in the stack is assigned as the base unit, the MAC address of the 
new base unit (with offset) now applies to the stack configuration. The original 
stack IP address still applies to the new base unit.
For an example of a BootP configuration file, see 
.”