Murphy EVS-A Folheto

Página de 2
 
Warranty - A limited warranty on materials and workmanship for one year is given with this FW Murphy product.  A copy of the 
warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm 
 
 
Specifications 
Environmental 
ƒ Operating 
Temperature:-40
°F to 185°F (-40°C and +85°C). 
ƒ 
Humidity:  0-95% non-condensing 
ƒ 
Vibration:  30 g’s (Mechanical stability) 
Power Requirements 
Murphy EVS-SB – Internal Battery Power 
ƒ 
Battery power provided via 7.2V V lithium-Ion cell(s) 
ƒ 
Open circuit maximum voltage of 10VDC. 
ƒ 
Batter Life – 1 year under normal operation 
ƒ 
Normal operation 10v> Vbat> 6.4v 
ƒ 
Low battery mode:  5.0v< Vbat< 6.4v 
ƒ 
System shutdown and alarm mode active below 5.0v 
Murphy EVS-A, EVS-S – External DC Power 
ƒ 
External power:  8-32 VDC 
ƒ 
Input Current:  100mA Max 
Product Accuracy 
ƒ 
±5% of full scale at 1.5 ips and 21 deg C. 
ƒ 
±5% Variation over temperature from 21 deg C, over 
operating range.. 
ƒ 
Integration Stage End-to-End Noise:  <0.01 ips RMS 
Murphy EVS-S and EVS-A 
ƒ 
±5%, at Bandwidth of 6 to 500 Hz from 50Hz calibration 
point 
ƒ 
±3dB at Bandwidth of 3 to 875 Hz, worst case 
Murphy EVS-SB 
ƒ 
±5%, at Bandwidth of 6 to 350 Hz from 50Hz calibration 
point 
ƒ 
±3dB at Bandwidth of 3 to 875 Hz, worst case 
Trigger Feature 
ƒ 
Trigger level between 0.1 and 1.5 inches per second (ips) 
Peak 
ƒ 
Trigger set with single turn adjustable PC board mount 
potentiometer 
ƒ 
PC board marked with 15 marks corresponding to 0.1 to 1.5 
in 0.1 increments 
Time Delay Feature 
ƒ 
Adjustable from 0 to 10 seconds 
ƒ 
Set with adjustable single turn PC board mount 
potentiometer 
ƒ 
PC board marked with 11 marks corresponding to 0 to 10 
seconds in 1 second intervals 
Output 
ƒ 
Normally-Open and Normally-Closed outputs simultaneously 
available 
ƒ 
Open-collector outputs sink to Common Ground 
ƒ 
50 mA sink capacity 
ƒ 
Input voltage:  40 VDC maximum 
ƒ 
Switch output is selectable for latched or non-latch 
configurations.  Reset accomplished by reset pushbutton or 
external contact closure when in latch mode. 
ƒ 
Shutdown Alarm activated on power loss 
LED Outputs 
Alarm LED output 
ƒ 
Red LED  
ƒ 
LED strobing for first 5 minutes after entering Alarm mode 
ƒ 
Flashing thereafter until Reset activated 
ƒ 
Strobe rate:  2mSec on, every 0.5 
±0.25 seconds 
ƒ 
Flash rate:  2mSec on, every 6 
±1 seconds 
Power LED output 
ƒ Green 
LED 
ƒ 
Flash Duration:  2mSec 
Murphy EVS-S and EVS-A 
ƒ 
Flash once every 6 
±1 seconds 
Murphy EVS-SB 
ƒ 
Battery status “Normal”: Flash once every 6 
±1 seconds 
 
Battery in “Low-Battery” range:  Flash once every 12
±1 
seconds 
4-20mA output (EVS-A only) 
ƒ 
Power obtained from power supply 
ƒ 
Loop Resistance:  600 ohms max at 24 V and 20mA. 
ƒ 
Current loop accuracy 
±5% from internal setpoint 
ƒ 
20 ma corresponds to 1.5 ips Peak 
ƒ 
4 ma corresponds to 0 ips Peak 
Reset 
ƒ 
Local reset switch w/momentary contact 
ƒ 
External reset:  Available via header and will require an 
external relay or pushbutton contact to ground to activate the 
reset. 
ƒ 
Activation Period:  Reset must be active for 0.5 sec. 
minimum to reset the switch. 
Circuit Functional blocks 
ƒ 
Charge Amp interface 
- The input Transducer is an integrated PZT element for 
measuring acceleration with an internal charge converter. 
- Maximum G level of 13 g’s at 500hz 
ƒ Bandpass 
Filter 
- Frequency response dependent on model number (refer to 
“Product Accuracy”) 
ƒ Integration 
- Integration to convert from G to IPS peak 
Approvals 
ƒ 
Hazardous Area approvals applied for.  (refer to “Product 
Table”) 
 NMEA 
Product Dimensions and Sensitivity Axis