Chapter 4
Register-Level Programming
© National Instruments Corporation
4-5
PC-DIO-96 User Manual
Register Description for the Interrupt Control Registers
There are two interrupt control registers on the PC-DIO-96.  One of these registers has individual
enable bits for the two interrupt lines from each of the 82C55A devices.  The other register has a
master interrupt enable bit and two bits for the timed interrupt circuitry.  Of the latter two bits,
one bit enables counter interrupts, while the other selects counter 0 or counter 1.  The bit maps
and signal definitions are listed as follows.