Netgear NETGEAR Manual Do Utilizador

Página de 400
User Manual for the NETGEAR 7300S Series Layer 3 Managed Switch Software 
12-10
Managing Switch Stacks
202-10088-01, March 2005
Stacking Recommendations
The purpose of this section is to collect notes on recommended procedures and expected behavior 
of stacked FSM7328S/FSM7352S. Procedures addressed initially are listed below. 
Initial installation and power-up of a stack. 
Removing a unit from the stack
Adding a unit to an operating stack
Replacing a stack member with a new unit
Renumbering stack members
Moving the master to a different unit in the stack
Removing a master unit from an operating stack
Merging two operational stacks
Preconfiguration
Upgrading firmware
Migration of configuration with a firmware upgrade
Stack master election specifically determined by 
the MAC address
• Assuming that both stack members have the 
same priority value and software image, restart 
both stack members at the same time.
The stack member with the higher MAC address is 
elected stack master.
Add a stack member
• Power off the new switch
• Through their stacking ports, connect the new 
switch to a powered-on switch stack.
• Power on the new switch.
The stack master is retained. The new switch is 
added to the switch stack.
Stack master failure
• Remove (or power off) the stack master.
Based on "Stack Master Election and Re-Election" 
on page 5, o
ne of the remaining stack members 
becomes the new stack master. All other stack 
members in the stack remain as stack members 
and do not reboot.
Table 12-2.
Switch stack configuration scenarios  (continued)