3com 5500-SI Manual Do Utilizador

Página de 686
File Attribute Configuration 439
File Attribute
Configuration
You can assign the main/backup attribute to a file so as to use this file as the 
main/backup startup file upon next startup of switch, check the main and backup 
files, and toggle between the main and backup attributes of file.
You can use an App, BootROM, or Web file on one unit in the fabric to update all 
other units in the fabric. You can easily update the key software (including App, 
BootROM and Web) on the whole fabric through CLI (command line interface).
Perform the following operations in user view (among which, the display commands 
can be executed in any view).
You can assign the main/backup attribute to a file on the whole fabric only when the 
file exists in all the switches of the fabric.
The assignment of the main or backup attribute to a Web file takes effect 
immediately without the need of restarting the switches.
Currently, the configuration files use .cfg as the extension names, and are stored in 
the root directory of the storage.
Table 473   Assign attributes to files
Operation
Command
Description
Assign the main attribute to a file so 
as to use this file as the main boot 
file upon next startup
boot boot-loader 
file-url [ fabric ]
Optional
Assign the backup attribute to a file 
so as to use this file as the backup 
boot file upon next startup
boot boot-loader 
backup-attribute 
file-url [ fabric ]
Optional
Assign the main or backup attribute 
to a Web file so as to use this file as 
the main or backup Web file upon 
next startup.
boot web-package 
webfile { backup | main 
}
Optional
Assign the main or backup attribute 
to a configuration file so as to use 
this file as the main or backup 
configuration file upon next startup.
startup 
saved-configuration
 
cfgfile [ backup | main ]
Optional
Executing this command with 
neither backup nor main 
keyword will assign the main 
attribute to the configuration 
file by default.
Configure the switch(es) to use null 
configuration file upon next startup
undo startup 
saved-configuration
 [ 
unit unit-id ]
Optional
Toggle between the main and 
backup attributes of file
boot attribute-switch { 
all | app | 
configuration | web }
Optional
Enable the user to enter the main 
Boot Menu with customized 
password
startup bootrom-access 
enable
Optional
By default, the user is disabled 
from entering the main Boot 
Menu with customized 
password.
Display the information about the 
App boot files
display boot-loader 
unit unit-id ]
Optional
You can execute the display 
commands in any view.
Display the information about the 
startup configuration files
display startup unit 
unit-id ]