Installation and Troubleshooting 2 - 11
Installing the ONline System Concentrator
The ONline System Concentrator can be placed on top of a table or a shelf, 
or mounted in a rack.  Make sure the cable tray has been installed first on 
the table or in the rack (or that 1 3/4" (4.5 cm) of vertical space has been 
provided below the unit for air flow) and that the location meets all the 
environmental considerations specified earlier in this chapter.
Caution:
3Com recommends that two people install the unit 
since it weighs 38 lbs (17 kg) with one power supply 
and 46 lbs (24 kg) with the backup power supply 
installed.
3Com also recommends installing the backup power supply 
prior to rack mounting the unit (see the section titled 
Installing the Backup Power Supply later in this chapter).  In 
some rack cabinets, the rear of the cabinet may interfere 
with installation or removal of the power supply and fan.
Rack Mounting the ONline System Concentrator
The ONline System Concentrator can be mounted in four different 
configurations in the rack.  Use the same rack settings for both the cable 
tray and the concentrator.  If you are not installing the cable tray in the 
rack, you should select the concentrator mount setting at this time.  Refer 
to Table 2-2 and Figure 2-2 in the “Cable Tray Rack Mounting” section for 
specifics about the four mounting settings.
Follow the steps below to mount the concentrator in your rack:
1.
Attach the two rack mount flanges to the ONline concentrator unit in 
the position you want as shown in Figure 2-4 using the eight (8) 
provided 8-32 x 1/4" flathead screws - four per side.