Panasonic AV-HS300G Manual Do Utilizador

Página de 64
35
3. Setup
3-5. Setting the sync signals
The sync signals to be used by the system can be selected.
External sync:   For synchronization with an external sync signal (gen-lock). The reference input signal is 
looped through and output.
BBST:  Black burst signal (vertical phase of 0H)
BBAD:   Black burst signal 
This can be selected when HD format signals are supplied. 
( Vertical phase of 90H when the 59.94i or 59.94p format is selected;  
vertical phase of 75H when the 50i or 50p format is selected)
TRI
 Tri-level sync signal (vertical phase of 0H) 
This can be selected when HD format signals are supplied.
Internal sync:   For synchronization with an internal reference signal (INT). The REFOUT signal (black burst 
signal) is output from the two reference connectors.
1
  Press the [FUNC] switch to light its indicator, and then press the [SETUP] switch to display the SETUP 
menu.
2
 Turn [F1] to display the REF menu.
3
  Turn [F], select the sync signal using the SYNC item, and press the [F4] switch (EXEC) to enter the 
selection. 
An asterisk ( ) appears at the left of the reference signal currently selected.
BBAD
 TRI 
 INT 
REF
 5/15 
SYNC
 BBST 
GL
EXEC
 -
An asterisk ( ) appears at the GL item when operation is synchronized with the external or internal sync 
signals.
A dash (–) appears at the GL item when operation is not synchronized with the external or internal sync 
signals.