Maximum attenuation includes attenuation and the 
loss induced by other components such as connec-
tors, splices, and the mating of unlike fiber types. 
Although some 2 km (1.25 miles) cables have a total 
attenuation of less than 11.0 dB, the 2 km (1.25 
miles) inter-station distance must be maintained to 
comply with modal bandwidth requirements.
The maximum attenuation value in this table is based 
on a cable diameter of 62.5, 80 or 100 
mm
.
The following table shows alternative Multi-Mode 
fiber types that can be used.
If you are using fiber with a diameter of 50 
mm
 and 
have 3Com equipment at both ends of the link, sub-
stitute 8.0 dB for the maximum attenuation. If 3Com 
equipment is only at one end, substitute 6.0 dB for 
the maximum attenuation value.
If you are using equipment at the end of the link from 
a vendor other than 3Com, you must perform a sepa-
rate loss budget analysis. Contact the vendor(s) for 
values to use in your analysis.
Does the Cable Provide Sufficient Bandwidth?
Bandwidth for multi-mode fiber is referred to as 
modal bandwidth because it varies with the modal 
field (or core diameter) of the fiber. 
Modal bandwidth is specified in units of MHz.km, 
which indicates the amount of bandwidth supported 
by the fiber for a 1 km (0.625 miles) distance. Your 
cable must have a Modal bandwidth of 500 MHz, 
which allows the cable to support end-to-end band-
width of 250 MHz at the maximum 2 km (1.25 miles) 
distance.
To check that the bandwidth of your fiber is within an 
acceptable range:
1
Divide the amount of bandwidth available according 
to the fiber specification by the total length of fiber 
(km). 
2
If the result is lower than 250 MHz, the link may be 
prone to bit errors. You should shorten the length of 
the fiber or use a different fiber until the result of the 
calculation reaches 250 MHz.
Example
A cable with modal bandwidth of 500 MHz.km will 
have 250 MHz of bandwidth at 2 km (1.25 miles). 
Output power (from transceiver)
-20 dB minimum
-14 db maximum
Receiver power
-31 dB minimum sensitivity
-14 dB maximum sensitivity
Core (mm)
Cladding (mm)
Numerical Aperture
50
125
0.20
50
125
0.22
85
125
0.28
100
140
0.29
Specification
Description