Power-Up Disabled Option Switch
3-13
Power-Up
Disabled Option
Switch
Disabled Option
Switch
If network management is present, an external switch on the hub’s rear panel
allows you to power-up the hub with the ports disabled. The power-up
disabled option switch is located between the expansion connectors and the
DC input connector, as shown in Figure 3-12.
allows you to power-up the hub with the ports disabled. The power-up
disabled option switch is located between the expansion connectors and the
DC input connector, as shown in Figure 3-12.
This feature cannot be fully implemented unless a network management
device (such as the LinkBuilder FMS 100 Management Unit) is connected to
the hub stack. If no network management is present, leave the power-up
disabled option switch in the enabled position (set to E).
device (such as the LinkBuilder FMS 100 Management Unit) is connected to
the hub stack. If no network management is present, leave the power-up
disabled option switch in the enabled position (set to E).
Figure 3-12 Power-Up Disabled Option Switch
Table 3-4 describes the functioning of the power-up disabled option switch.
You can use this option for security purposes. For example, you can disable a
port where a faulty device or other problem exists. This prevents the disabled
port from receiving any data when the hub is powered-up. Conversely, you
can enable ports if you want them to receive data.
port where a faulty device or other problem exists. This prevents the disabled
port from receiving any data when the hub is powered-up. Conversely, you
can enable ports if you want them to receive data.
tion
A
–12
0.2
UP
DOWN
EXPA
DC INPUT
E
D
Power-up disabled
option switch
option switch
Table 3-4 Settings on Power-Up Disabled Option Switch
Setting
Result
D (disabled)
If network management is present, you can enable specific ports
after the hub has been powered-up.
after the hub has been powered-up.
If network management is not present, all ports remain disabled
after the hub has been powered-up.
after the hub has been powered-up.
E (enabled)
This is the default setting. All ports are enabled after the hub has
been powered-up, whether or not network management is present.
If network management is present, individual ports can then be
disabled after the hub has been powered-up.
been powered-up, whether or not network management is present.
If network management is present, individual ports can then be
disabled after the hub has been powered-up.