Power-Up Disabled Option Switch
3-13
Power-Up 
Disabled Option 
Switch
If network management is present, an external switch on the hub’s rear panel 
allows you to power-up the hub with the ports disabled. The power-up 
disabled option switch is located between the expansion connectors and the 
DC input connector, as shown in Figure 3-12.
This feature cannot be fully implemented unless a network management 
device (such as the LinkBuilder FMS 100 Management Unit) is connected to 
the hub stack. If no network management is present, leave the power-up 
disabled option switch in the enabled position (set to E).
Figure 3-12   Power-Up Disabled Option Switch
Table 3-4 describes the functioning of the power-up disabled option switch.
You can use this option for security purposes. For example, you can disable a 
port where a faulty device or other problem exists. This prevents the disabled 
port from receiving any data when the hub is powered-up. Conversely, you 
can enable ports if you want them to receive data. 
tion
A
–12
0.2
UP
DOWN
EXPA
DC INPUT
E
D
Power-up disabled
option switch
Table 3-4   Settings on Power-Up Disabled Option Switch
Setting
Result
D (disabled)
If network management is present, you can enable specific ports 
after the hub has been powered-up.
If network management is not present, all ports remain disabled 
after the hub has been powered-up.
E (enabled)
This is the default setting. All ports are enabled after the hub has 
been powered-up, whether or not network management is present. 
If network management is present, individual ports can then be 
disabled after the hub has been powered-up.