EMC DS-32B2 Manual Do Utilizador

Página de 574
1
fanShow
1-149
Telnet Commands
fanShow
Display fan status.
Syntax
fanShow
Availability
All users
Description
Use this command to display the current status of the switch fans. 
The format of the display varies according to the number of fans 
installed. Some switch models show fan speed measured in RPM.
Fan status is shown as:
The output from this command varies depending on switch type and number 
of fans present.
Operand
None
Example
To display the status and RPMs for the fans:
switch:admin> fanShow
Fan 1 is OK, speed is 2721 RPM
Fan 2 is OK, speed is 2721 RPM
Fan 3 is OK, speed is 2657 RPM
See Also
fanDisable
fanEnable
psShow
tempShow
chassisshow
OK
Fan is functioning correctly.
absent
Fan is not present.
below minimum
Fan is present but rotating too slowly or stopped.
unknown
Unknown fan unit installed.
faulty
Fan has exceeded hardware tolerance.