loopdiagStart
1-237
Telnet Commands
loopdiagStart
Start loopdiag application.
Syntax
loopdiagStart port
Availability
Admin
Description
Use this command to start the loopdiag application at the port 
specified. It will isolate the loop device before running diagnostics 
and report the test result. Error/failure and statistics will be reported.
The port must be online prior to initiating the command. The 
command will place the port in testing mode and put the port back 
online at the end of the test. In the cases when failure occurs in the 
management layer, users should issue 
loopdiagClear
 to clear any 
information from the failure.
Operand
This comand has the following operand required:
Example
To start the loopdiag application at port 5:
switch:admin> loopdiagStart 5
See Also
loopdiagClear
loopdiagDone
loopdiagStop
port
The physical port number where the loopdiag 