EMC DS-32B2 Manual Do Utilizador
1
loopdiagStart
1-237
Telnet Commands
loopdiagStart
Start loopdiag application.
Syntax
loopdiagStart port
Availability
Admin
Description
Use this command to start the loopdiag application at the port
specified. It will isolate the loop device before running diagnostics
and report the test result. Error/failure and statistics will be reported.
specified. It will isolate the loop device before running diagnostics
and report the test result. Error/failure and statistics will be reported.
The port must be online prior to initiating the command. The
command will place the port in testing mode and put the port back
online at the end of the test. In the cases when failure occurs in the
management layer, users should issue
command will place the port in testing mode and put the port back
online at the end of the test. In the cases when failure occurs in the
management layer, users should issue
loopdiagClear
to clear any
information from the failure.
Operand
This comand has the following operand required:
Example
To start the loopdiag application at port 5:
switch:admin> loopdiagStart 5
See Also
loopdiagClear
loopdiagDone
loopdiagStop
loopdiagDone
loopdiagStop
port
The physical port number where the loopdiag
application executes. This operand is required.