Siemens SCALANCE XB-200 Manual Do Utilizador

Página de 60
Upkeep and maintenance 
 
5.2 Restoring the factory settings 
 
SCALANCE XB-200 
30
 
Operating Instructions, 02/2015, C79000-G8976-C359-01 
5.2 
Restoring the factory settings 
Follow the steps below to reset the device parameters to the factory settings: 
 
 
Note 
When you reset the device parameters, all previously changed settings are lost. 
 
1.  Turn off the power to the device. 
2.  Press the "RESET" button for example with a screwdriver and reconnect the power to the 
device while holding down the button. 
3.  Hold down the button until the red fault LED "F" stops flashing after approximately 40 
seconds and is permanently lit. 
4.  Release the button and wait until the fault LED "F" goes off. 
The device starts automatically with the factory settings.