Upkeep and maintenance
5.2 Restoring the factory settings
SCALANCE XB-200
30
Operating Instructions, 02/2015, C79000-G8976-C359-01
5.2
Restoring the factory settings
Follow the steps below to reset the device parameters to the factory settings:
Note
When you reset the device parameters, all previously changed settings are lost.
When you reset the device parameters, all previously changed settings are lost.
1. Turn off the power to the device.
2. Press the "RESET" button for example with a screwdriver and reconnect the power to the
2. Press the "RESET" button for example with a screwdriver and reconnect the power to the
device while holding down the button.
3. Hold down the button until the red fault LED "F" stops flashing after approximately 40
seconds and is permanently lit.
4. Release the button and wait until the fault LED "F" goes off.
The device starts automatically with the factory settings.