Technical Specifications
Performance
Data Rate:  10Mbits / sec
Partitioning:  Enforced after 32 consecutive collisions.
Reconnect:  Occurs after 512 bits of error-free transmission.
Network Standards
Ethernet V1.0/V2.0 IEEE 802.3:  10BASE-T, 10BASE5
10BASE2,    
10BASE-FL & FOIRL.
(Magnum Workgroup Hubs are physical layer standard Ethernet products,
and operate independently of all software.)
Maximum Ethernet Segment Lengths
DTE (AUI Drop Cable)
-   50 m (164 ft)
10BASE-T (twisted pair)
-  100 m (328 ft)
Shielded twisted pair
-  150m (492 ft)
10BASE2 ThinNet (BNC)
-  185 m (607 ft)
10BASE5 ThickNet 
-  500 m (1,640 ft)
FOIRL multi-mode Fiber optic
-  1 km (3,281 ft)
10BASE-FL multi-mode Fiber optic 
-  2 km (6,562 ft)        
Single-mode Fiber optic
-  10 km (32,810 ft)
Connectors
TP :
RJ-45 shielded, female
AUI:
D-sub 15-pin female with slide lock
Other Media: via Port Modules
AC Power:   IEC recessed male
Switches
Port 1, up-link switch for repeater-to-repeater connections.
LEDs
PWR (AC power on), ACT (common activity indicator), LINK (per port)
Operating Environment
Ambient Temperature:  32
° to 120° F (0° to 50°C)
Storage Temperature:  -5
° to 140°F (-20°to 60°C)
Ambient Relative Humidity:  10% to 95% (non-condensing)
Packaging
Enclosure:  High strength metal.  Suitable for wiring closet shelf, 
desktop, or rack-mounting.
Dimensions:   1008:   
[8.5 x 7.75 x 1.75] in, [21.6 x 19.7 x 4.5] cm
1016 
&
 1024:[17.0 x 7.5 x 1.75] in, [43.2 x 19.1 x 4.5] cm 
Weight:
1008:
3.4 lbs, 1.6 kg
1016:
3.1 lbs, 1.4 kg
1024:
3.3 lbs, 1.5 kg
Cooling method:  Convection