Magnum DS50 / DS60s Dual Speed Hubs                  Installation and User Guide (06/02)
 
Each Magnum DS50 / DS60 Dual-speed Hub Plus is shipped with two mounting 
brackets (and screws), to allow the unit to be mounted in nearly any desired orientation or 
position.  The brackets are attached to the unit’s case with one of the metal screws for each 
bracket.  It is recommended that the brackets be attached to two opposite corners on the unit. 
The brackets should be attached to the Magnum DS50 / DS60 through the round hole of the 
bracket.  When properly attached, the brackets will extend slightly below the base of the unit to 
allow clearance for the rubber feet. 
 
3.1.2 
Optional mounting methods, DIN-rail and E-Stand 
A) 
For DIN-rail mounting, a kit is needed that uses the metal mounting brackets (see 
3.1.1 above) to attach DIN-rail clips that hold the unit in a vertical position, Ethernet 
cables attaching at the bottom.  For additional information on DIN mounting, email 
  
B) 
 The E-Stand  provides a 
vertical mounting option for 
the DS50 / DS60s. When 
horizontal placement is not 
possible or desirable (such as 
when the unit is placed on a 
carpeted floor, which would 
potentially block air flow 
from the cooling fan), the E-
Stand offers a convenient 
installation option. Simply 
align the rectangular cut-out on the E-Stand with the air vent on either side of the 
DS50 / DS60. The E-Stand also allows the DS50 / DS60 unit to be securely mounted 
via two screws that connect through the E-Stand and into the side of the unit.  
 
M
a
gn
um
 D
S
60
P
e
rs
on
a
l H
u
b
 P
lus
G
A
R
R
E
T
T
=
    
 x
1
0
  
  
         1
0
0
UP
L
IN
K
Mb
/s
L
IN
K
       
  
  
 R
X
L
IN
K
    
  
      R
X
L
IN
K
  
  
  
      R
X
L
IN
K
       
  
  
 R
X
L
IN
K
       
  
  
 R
X
RX
LI
N
K
CO
L
PW
R
1
2
34
5
6
Screw holes
Rectangular
cut-out
(Air Vent)
 
3.2 
Ethernet Media, connections and Specifications 
The Magnum DS50 / DS60 Dual-speed Hub Plus can be connected to the following 
three media types: 100BASE-TX, 10BASE-T and 100BASE-FX.  CAT 5 cables should be used 
when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 
may be used.  In either case, the maximum distance for unshielded twisted pair cabling is 100 
meters (328 ft). For fiber port 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling 
can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling 
supports much longer cable distance and higher bandwidths as compared to copper wiring. 
 
 