Fujitsu MB88121 SERIES Manual Do Utilizador

Página de 73
SK-91F467-FLEXRAY V1.1 
Jumpers and Switches 
FMEMCU-UG-910017-11 
- 36 - 
© Fujitsu Microelectronics Europe GmbH 
3.11 Reset Generation 
A system reset can be generated in different ways. The first possibility is to press the user 
reset push button (SW1). Secondly the supply monitor will generate a reset if an unusual 
voltage is detected and third a reset is raised if a UART that does a reset is selected. 
If a system reset is done, it will be displayed by the red reset LED (D18). 
The system reset will do a simultaneous reset of the microcontroller and the FlexRay 
communication controller. The MCU and / or the FlexRay CC can be disconnected from the 
system reset signal with two jumpers. 
The Reset push button can be used in two modes:  
no delay of Reset 
press Reset button 2s 
The selection is done by solder Jumper JP96. 
JP52  Connects the FlexRay CC to the system reset signal (SK91F467-FLEXRAY) 
JP54  Connects the MCU to the system reset signal 
 
Jumper 
Setting 
Description 
ON (closed) 
Reset is connected to FlexRay CC RST 
JP52 
OFF (open) 
No connection to the FlexRay CC 
ON (closed) 
Reset is connected to MCU INITX 
JP54 
OFF (open) 
No connection to the MCU 
1-2 
Reset is generated when SW1 is pressed 
JP96 
2-3 
Reset is generated after SW1 is pressed 2s 
Default: grey 
Table 3-22: Reset Connections 
 
The triple supply monitor on-board has the possibility to watch 5V, 3.3V and the third voltage 
is user configurable 2.5V or 1.8V. If any voltage has a failure, a system reset will be done. 
JP42  Monitoring of 1.8V supply voltage 
JP43  Monitoring of 2.5V supply voltage 
Jumper 
Setting 
Description 
ON (closed) 
Vcc1V8 connected to supply monitor 
JP42 
OFF (open) 
Vcc1V8 not connected to supply monitor 
ON (closed) 
Vcc2V5 connected to supply monitor 
JP43 
OFF (open) 
Vcc2V5 not connected to supply monitor 
Default: grey 
Table 3-23: Supply Monitor Settings 
By default 2.5V supply will be monitored. 
 
The system reset also can be done via any UART. Therefore the user has the possibility to 
select one of the three on-board UARTs.