User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 10
CLI Command
To enable an element using the CLI, enter the following command from 
Configure mode:
set fabric configure-redundant-hardware enable
Configuring Supervisor Module Redundant 
Ethernet Console IP Addresses
Web Agent 
Procedure
If you need to communicate with both the Active and Standby Supervisors, 
configure an alternate Ethernet Console IP address for both. Configure an 
alternate IP address for both slot 1 and 2 CPU’s, by using the Web Agent or 
the CLI.
* Note:  Do not Login to a Standby Supervisor module to manage the 
switch. The Standby Supervisor does not have accurate switch 
status information until it becomes the Active Supervisor.
To identify the Active or Standby supervisor, look at the LED 
display (marquee), or open the System > Configuration > 
CPU Redundancy > Status/Statistics
 folders from the Web 
Agent, or use the show CPU status
 
CLI command.
To configure a redundant console IP address by using the Web Agent:
1.  In the navigation pane, expand the System > Configuration > CPU 
Redundancy folders, and then click Configuration. The CPU 
Redundancy Configuration Web page is displayed in the content pane. 
Se
.
Figure 10-6.  CPU Redundancy Configuration Web Page