Avaya 580 Manual Do Utilizador

Página de 782
User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
22-1
22
Monitoring and Configuring 
the Forwarding Cache 
Overview
Contents
The information and procedures provided in this chapter pertain to layer 3 
module configuration only:
For more information about the CLI commands that are mentioned in this 
chapter, see Command Reference Guide for the Avaya P580 and P882 
Multiservice Switches, Software Version 6.1
10-Gigabit Module 
and Forwarding 
Cache
Because of the volume of traffic that the 10-Gigabit module can process and 
its internal architecture, the module can cause the number of entries in the 
Layer 3 forwarding cache to reach the default maximum of 130,000 sooner 
than other modules. Once the maximum is reached: 
The switch routes all new traffic flows by means of the slow path. 
The speed at which traffic is forwarded is decreased.
The role of master virtual router may be transferred from one VRRP 
router to another if VRRP is enabled. 
The following message is displayed in the CLI if debug mode is 
enabled and in the event log if logging of CLI debug messages is 
enabled: 
Log entry <number> by event 2 at <date and 
time> : Normal(0) 
Description: OS Error -- FILE: p2_ipenv.c 
LINE: 752 Value 0x2 : IP timer got skewed
(Use the logging protocol event cli debug command to enable 
logging of CLI debug messages.) 
This issue is most prevalent when the 10-Gigabit module as well as the rest 
switch is processing a high volume of layer 3 traffic flows.