Avaya C360 Manual Do Utilizador

Página de 286
Chapter 7
 116
Avaya C360 Manager User Guide
Oper Status
The operational status of the interface. 
Possible statuses include:
• Up - The interface is up and can transmit 
and receive packets.
• Down - The interface is down due to 
some failure, and cannot transmit or 
receive packets.
• Testing - The interface is in testing mode 
and cannot transmit or receive regular 
data.
• Standby - The interface is a backup 
interface and cannot transmit or receive 
packets unless the primary interface it 
backs up fails.
• Disabled - The interface is disabled. It 
cannot transmit or receive packets.
• Partially Down - The interface is up. 
However, some interfaces (or PVCs) 
layered on top of this interface are Down. 
Some packets can be transmitted and 
received.
MTU (octets)
The size (in octets) of the largest datagram 
that can be sent via the interface.
Last Fault Message
The type of error last occurring on the 
interface. Possible values are:
• Unknown Error
• Receive Short
• Receive Long
• Illegal Address
• Unknown Address
• DLCMI Protocol Error
• DLCMI Unknown IE
• DLCMI Sequence Error
• DLCMI Unknown Rpt
• No Error Since Reset
Time Since Fault
The amount of time the system was up before 
the last error occurred.
Table 7-11.  USP Dialog Box - Frame Relay Parameters (Continued)
Field 
Description