Sample Type
The method used for monitoring the variable. Possible 
options are:
• Rate - The alarm uses the counter’s rate in the last 
interval.
• Total - The alarm uses the absolute number of the 
counter from the time the device was last reset.
* Note:  The Alarms and Events tool can only 
configure alarms using the Rate method. To 
configure alarms based on the absolute 
number of packets, use the CLI (Command 
Line Interface) or a third-party application.
Startup Alarm
The type of event that can be generated as the first event 
for the alarm. Possible types are:
• Rising - The first event that can be generated must 
be a Rising Event. If the rate falls below the Falling 
Threshold before it rises above the Rising Threshold, 
a Falling Event is not generated.
• Falling - The first event that can be generated must 
be a Falling Event. If the rate rises above the Rising 
Threshold before it falls below the Falling Threshold, 
a Rising Event is not generated.
• Rising and Falling - The first event generated can 
be a Rising or a Falling Event.
Rising Threshold
The upper threshold for the counter. 
Falling Threshold
The lower threshold for the counter. 
Owner
The owner of the alarm. This is usually the person who 
created the alarm.
Table 7-1.  Alarms Table Fields (Continued)
Field
Description