Avaya M770 Manual Do Utilizador
Chapter 4
Managing Miscellaneous Commands
34
Avaya M770 ATM Switch User’s Guide
Resetting the saved switch prefix
You can reset the saved switch prefix to current address. This prevents the current
address from changing even after a reset.
To reset the saved switch prefix, use the
address from changing even after a reset.
To reset the saved switch prefix, use the
address reset
command.
Setting the switch prefix to its default value
The default prefix is 39.00.00.00.00.00.00.xx.xx.xx.xx.xx.xx where x is the MAC
address of the switch master agent module.
address of the switch master agent module.
To change the switch prefix for the M770 ATM Switch to its default value, use the
address default
command.
Note:
You must reboot the switch before the above command will take affect. You
must update all the other affected switches’ static routing table entries with the new
switch prefix. If you are using PNNI routing then the affected routing entries will be
updated automatically.
switch prefix. If you are using PNNI routing then the affected routing entries will be
updated automatically.
Viewing or changing the IP time server address
A time server is a server that provides the date and time, as specified by RFC 868,
such as a UNIX machine running ‘timed’ to the M770 ATM Switch. You must
provide the M770 ATM Switch with the IP address of a time server or set the M770
ATM Switch to discover the server on the network by broadcasting requests. To
view the time received from the time server, use the
such as a UNIX machine running ‘timed’ to the M770 ATM Switch. You must
provide the M770 ATM Switch with the IP address of a time server or set the M770
ATM Switch to discover the server on the network by broadcasting requests. To
view the time received from the time server, use the
system time
command (refer
to Chapter 17, “Managing System Commands” for details). To view the current time
server, use the
server, use the
ip timeserver
command.
To set or change the time server, use the
ip timeserver
command.
Command:
M15-155s8:/>address reset
Command:
M15-155s8:/>address default
Output:
Done.
Command:
M15-155s8:/>ip timeserver
Output:
The M770 is requesting the time from a server at
192.16.1.14
The M770 will use the first time server that responds to a
broadcast request.
Command:
M15-155s8:/>ip timeserver [<address> | discover]
Parameters:
<address>
This enables you to specify the IP address of the time server.
discover
This enables the M770 ATM Switch to discover the server by
broadcasting requests.
broadcasting requests.