Avaya 882 Manual Do Utilizador

Página de 782
21-6
User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
Chapter 21
4.  Click APPLY.
Table 21-2.  Event Classes
Class
Determines whether the switch sends a 
notification for...
Start
Starts of the system.
System
System events. 
Configuration
Each configuration change (for example, enabling 
and disabling ports).
Temperature Status
Changes in temperature status. Temperature status 
messages could precede a switch shutdown, and 
are often critical.
Resource
Changes in system resources.
Fan Status
Fan status. Fan failures will eventually lead to 
overheating the system. The fan status message 
provides a good early warning for a failure that 
could eventually cause the switch to shut down.
Service Port Status and 
User Port Status
Status changes in service ports and user ports. 
Set a port as either a service port or user port on 
the Detailed Physical Port Configuration Web 
page. This feature makes it possible for you to use 
different notification levels for critical (service 
ports), if desired.
Power Status
The addition or removal of a power supply
Bridge Status
Changes in bridge status.
Switch Fabric
Failures in the switch fabric. These failures are 
critical and should be monitored closely.
OSPF
OSPF events if OSPF protocol event logging is 
enabled.
RIP 
RIP events if RIP protocol event logging is 
enabled.
LDAP
LDAP events if LDAP protocol event logging is 
enabled.
AppleTalk
AppleTalk events if AppleTalk protocol event 
logging is enabled.
Authentication Failure
Authentication failures. This is a security-related 
feature used to detect unauthorized SNMP activity.
1 of 2