Appendix A
A-2
User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
CAUTION:
Backing Up the Current Software
The Avaya Multiservice switches have two memory locations for storing 
the embedded switch software: APP1 and APP2. These two memory 
locations make it possible to store the current software in one APP location 
and download the new software to the other APP location. 
Saving the current software in one APP location ensures that you could run 
this earlier version of software, if you encounter any problem with the new, 
downloaded software. 
When upgrading the switch from v5.x application software to v6.0 or 
later, you must download v6.x to the APP2 memory location. If you 
download v6.x to APP1, and store v5.x software in APP2, the 6.x 
software is corrupted. Once v6.x software is successfully stored in 
APP2, you can download v6.x to APP1. 
Web Agent 
Procedure
To determine the versions of application software that are stored in APP1 
and APP2: 
1.  In the navigation pane, expand the System > Memory folders.
2.  Select FEPROM
The FEPROM Contents Web page is displayed in the content pane 
(
). The S/W Version field displays the version of application 