Workaround:  
Use the following table to determine the option that corresponds to 
the rate that you want to set.
Table 8.  Flood Rate Limiting on 80-Series 10/100 Modules
* Note:  Do not use the 20%, 40%, or 80% options of the Web 
Agent or CLI. 
Frames Transmitted with Cyclic Redundancy Check (CRC) 
Errors
Problem:  
For certain revisions of the Cajun P550R/P580/P880/P882 switch 
12- and 20-port module (Model M5520-100TX, module Type 9, 
revision level A or B and M5512-100TX, Revision A), a temperature 
sensitivity problem has been found when operating at 10 Mbps. This 
sensitivity results in the port transmitting frames with CRC errors. 
These frames, since they have CRC errors, are then dropped by the 
receiving station.
Workaround:  
The following legacy-cli command allows you to implement a new 
configuration to disable the power saving mode of the Phy chip. This 
has the same effect as moving the port’s operational temperature 
past the problem range. The new configuration is saved only in 
NVRAM:
> port set DisablePowerSave <port> on
* Note:  Except for this command, the Legacy-CLI is not 
supported by the Cajun Switch.
Desired Rate
Web or CLI Setting
80%
10%
40%
5%
20%
2%
10%
1%