McDATA 3232 Manual Do Utilizador

Página de 612
3
3-72
Diagnostics
MAP 0600: Port Failure and Link Incident Analysis
This MAP describes fault isolation for small form factor pluggable 
(SFP) transceivers and Fibre Channel link incidents. Failure 
indicators include:
One or more amber LEDs on the Fibre Channel ports illuminate.
The amber emulated LED adjacent to a port graphic at the 
Hardware View illuminates.
A blinking red and yellow diamond (failed FRU indicator) or 
yellow triangle (attention indicator) appears at the alert panel of 
the Product View or Hardware View.
An event code recorded at the Sphereon 3216/3232Event Log or 
the SANpilot event log.
A port operational state message or a Failed message at the Port 
Properties
 dialog box or SANpilot interface.
A link incident event code recorded at the console of an OSI 
server attached to the switch reporting the problem.
A link incident message at the Link Incident Log or Port Properties.
1
Was an event code 080, 081, 506507508, 512, or 514, observed at 
the Sphereon 3032/3232Event Log (EFC Server) or at the SANpilot 
event log?
NO
YES
Go to 
2
Was an event code 581582583584585, or 586 observed at the 
console of an OSI or FICON server attached to the switch reporting 
the problem.?
YES
NO
Go to 
3
The following table lists event codes, brief explanations of the codes, 