McDATA 3232 Manual Do Utilizador

Página de 612
4
4-10
Repair Information
— PWR - power supply. Chassis slots for redundant power 
supplies are 0 and 1. Power supplies are FRUs.
— FAN - cooling fan. Chassis slots for redundant fans are 0 
through 
3
. Fans are FRUs.
— CTP - control processor (CTP) card. The chassis slot is 0. The 
CTP card is not a FRU.
— THM - thermal sensor. The chassis slot is 0. The thermal 
sensor is not a FRU.
Position -
 a number representing the FRU chassis position. 
Chassis slots for power supplies are 0 and 1. Chassis slots for fans 
are 0 through 
3
 
inclusive. Chassis slots for SFPs are 0 through 
31
.
Action -
 the action performed (Inserted or Removed).
Part Number -
 the part number of the inserted or removed FRU.
Serial Number -
 the serial number of the inserted or removed 
FRU.
Product Manager 
Link Incident Log
The Link Incident Log (
) displays a history of Fibre Channel 
link incidents and associated port numbers for the switch. The 
information is useful to maintenance personnel for isolating port 
problems and repair verification.
To open the Link Incident Log, select Link Incident Log from the Logs 
menu on the navigation control panel.