McDATA 3232 Manual Do Utilizador

Página de 612
4
4-42
Repair Information
A McDATA-supplied power cord is provided for each switch 
power supply. To prevent electric shock when connecting the 
switch to primary facility power, use only the supplied power 
cord(s), and ensure the facility power receptacle is the correct 
type, supplies the required voltage, and is properly grounded.
2. Turn on both power switches at the rear of the unit. The unit 
powers on and performs power-on self-tests (POSTs).
NOTE: 
If two power cords are used for high availability, plug the cords 
into separate facility power circuits.
3. During POSTs:
a. The green power (PWR) LED on the switch front panel 
illuminates.
b. The amber system error (ERR) LED on the switch front panel 
blinks momentarily while the switch is tested.
c. The green LEDs associated with the Ethernet port blink 
momentarily while the port is tested.
d. The green and amber LEDs associated with the ports blink 
momentarily while the ports are tested.
4. After successful POST completion, the green power (PWR) LED 
remains illuminated and all other LEDs extinguish.
5. If a POST error or other malfunction occurs, go to 
 on page 3-6 to isolate the problem.
NOTE: 
When powering on the switch after removing and replacing a 
faulty FRU, the amber system error LED may remain illuminated. Clear 
the system error LED as part of the replacement procedure.
Power-Off Procedure
To power off the switch:
1. Notify the customer the switch is to be powered off. Ensure the 
customer’s system administrator quiesces Fibre Channel frame 
traffic through the switch and sets attached devices offline.
2. Set the switch offline (