CTP Card Events (400 through 499)
B-31
Event Code Tables
CTP Card Events (400 through 499)
Event Code: 400
Message:
Power-up diagnostics failure
Severity:
Major
Explanation:
The CTP power-on self test diagnostics detected a faulty FRU as indicated in the event data.
Action:
Replace the faulty FRU with a functional FRU. Perform the data collection procedure for the switch using the EFC 
Manager, and return the CD and the faulty FRU to McDATA for analysis and repair.
Event Data:
Byte 0: FRU code: 
01 = LBA
02 = CTP
03 = SBAR
05 = Fan module
06 = Power supply
08-0F = Port module
Byte 1: Slot position
Byte 2: Device ID
Byte 3: Power-up error code (Internally defined) (stored in the faulty FRU EEPROM for analysis)
Bytes 4-7: Power-up data code (Internally defined) (stored in the faulty FRU EEPROM)