McDATA 3232 Manual Do Utilizador

Página de 612
B
MPC Module Events (600 through 699)
B-67
Event Code Tables
MPC Module Events (600 through 699)
Event Code: 602
Message:
SBAR module anomaly detected
Severity:
Informational
Explanation:
Indicates that the control processor has detected a deviation in the normal operating mode or operating status of 
the indicated SBAR module.
Action:
No action required. There will be an additional event generated (604) if this event results in an SBAR logic failure.
Event Data:
Byte 0 = Slot position
Byte 1 = Anomaly reason code (See following chart)
Bytes 4-7 = Elapsed millisecond tick count
Bytes 8-9 = High Availability error callout #1
Bytes 10-11 = High Availability error callout #2
Byte 12 = Detecting port
Byte 13 = Connected port
Byte 14 = Participating SBAR
Bytes 16-17 =.High Availability error callout #3
Bytes 18-19 =.High Availability error callout #4
Distribution:
Switch
EFC Server
Host
Nonvolatile 
System 
Event Log
System 
Error 
Indicator
Event Log
E-Mail
Call-Home
Sense Info
Link Incident
Event #602 Anomaly Reason Codes
Reason Code
Description
Additional Data
0x00
Utility bus error to SBAR
HA Error Callouts (Words 2 & 4)
0x01
Utility bus error to Port Module
HA Error Callouts (Words 2 & 4)
0x02
Reserved
HA Error Callouts (Words 2 & 4)
0x03
SBAR module detected utility bus parity error
HA Error Callouts (Words 2 & 4)
0x04
Port module detected utility bus parity error
HA Error Callouts (Words 2 & 4)