McDATA 3232 Manual Do Utilizador
B
CMM Module Events (800 through 899)
B-73
Event Code Tables
CMM Module Events (800 through 899)
Event Code: 800
Message:
High-temperature warning (Port module thermal sensor).
Severity:
Major
Explanation:
The thermal sensor associated with the port module has detected that the "warm" temperature threshold level
has been surpassed.
has been surpassed.
Action:
Perform the data collection procedure for the switch using the EFC Manager, and return the CD to McDATA for
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
E-Mail
Call-Home
Sense Info
Link Incident
✔
✔
✔
✔
✔
✔
Event Code: 801
Message:
Critically hot temperature warning (Port module thermal sensor)
Severity:
Major
Explanation:
The thermal sensor associated with the port module has detected that the "hot" temperature threshold level has
been surpassed.
been surpassed.
Action:
Perform the data collection procedure for this switch using the EFC Manager, and return the CD to McDATA for
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
analysis. Perform a system power-on reset. If the problem persists, replace the switch.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
E-Mail
Call-Home
Sense Info
Link Incident
✔
✔
✔
✔
✔
✔