McDATA IPS4300 Manual Do Utilizador

Página de 188
5-2
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Removal and Replacement Procedures
ESD Procedures
Follow these ESD procedures:
If the product is connected to facility power (grounded), wear an 
ESD wrist strap and grounding cable connected to the product 
chassis.
If the product is not connected to facility power (not grounded), 
wear an ESD wrist strap and grounding cable connected to an 
approved bench grounding point.
Touch the product chassis once before performing a procedure, 
and once each minute during the procedure.
Store ESD-sensitive FRUs in antistatic packaging.
Field-Replaceable Units
 lists the concurrent FRU that is removed and replaced while 
the product is powered on and operational. The table also lists ESD 
precautions (yes or no) for the FRU, and references the RRP page 
number. Refer to 
 for FRU 
locations and part numbers.
Table 5-1
Concurrent FRU
Concurrent FRU
ESD Requirement
Page
Small form factor pluggable optical transceiver
Yes