McDATA IPS4300 Manual Do Utilizador

Página de 188
2
Installation Tasks
2-11
Installation Tasks
Configure Fabric 
Parameters
Perform this procedure to configure fabric operating parameters.
1. Set the product offline. Refer to 
 for instructions.
2. Select Switch and Fabric Parameters from the Configure menu at any 
view. The Fabric Parameters View displays (
).
Figure 2-5
Fabric Parameters View
a. At the R_A_TOV field, type a value between 10 through 1200 
tenths of a second (one through 120 seconds). Ten seconds 
(100) is the recommended value. The R_A_TOV value must 
exceed the E_D_TOV value.
b. At the E_D_TOV field, type a value between 2 through 600 
tenths of a second (0.2 through 60 seconds). Two seconds (20
is the recommended value.
NOTE: 
Fabric elements must be set to the same R_A_TOV and 
E_D_TOV values. An ISL between fabric elements with different 
values segments and prevents communication.
c. Select from the Switch Priority drop-down list to designate the 
fabric’s principal switch. The principal switch is assigned a 
priority of 1 and controls the allocation and distribution of 
domain IDs for all fabric elements (including itself). Available 
selections are DefaultPrincipal, and Never Principal.