McDATA IPS4300 Manual Do Utilizador

Página de 188
Maintenance Analysis Procedures
3-25
Maintenence Analysis Procedures
17
As indicated by event code 507, a port failed a loopback test. Reset 
the failed port.
a. At the EFCM Basic Edition interface:
1. Select Ports and Reset from the Maintenance menu at any 
view. The Reset View displays.
2. If necessary, use the vertical scroll bar to display the 
information row for the port.
3. Select (click) the check box in the Reset column.
4. Click OK. The port resets.
b. Perform an external loopback test for the reset port. Refer to 
.
Was the maintenance action successful?
NO
YES
The product port is operational. Exit MAP.
Go to 
.
18
A message appeared in the Link Incident Log or an event code 581
582583584585, or 586 was observed at the console of an OSI 
server attached to the product reporting the problem. Monitor port 
operation for approximately five minutes.
Did the link incident recur?
YES
NO
The problem is transient and the product port is operational. 
Exit MAP.
19
Clean fiber-optic components.
a. Inform the customer the port will be blocked. Ensure the system 
administrator quiesces Fibre Channel frame traffic and sets 
attached devices offline.
b. Block the port. Refer to 
c. Clean fiber-optic connectors. Refer to