McDATA IPS4300 Manual Do Utilizador

Página de 188
3-28
McDATA Sphereon 4300 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
2
A minor error occurred that caused the Fabric Services database to 
be re-initialized to an empty state, and a disruptive fabric logout and 
login occurred for all attached devices. Indications are:
Event code 011 - The Login Server database failed cyclic 
redundancy check (CRC) validation.
Event code 021 - The Name Server database failed CRC 
validation.
Devices resume operation after fabric login. Perform a data collection 
and contact the next level of support. Refer to 
Exit MAP.
3
As indicated by event code 051, a minor error occurred that caused 
the Management Server database to be re-initialized to an empty 
state and fail CRC validation. A disruptive server logout and login 
occurred for all attached devices.
Devices resume operation after Management Server login. Perform a 
data collection and contact the next level of support. Refer to 
Exit MAP.
4
As indicated by event code 061, a minor error occurred that caused 
the Fabric Controller database to be re-initialized to an empty state 
and fail CRC validation. The product briefly lost interswitch link 
capability.
Interswitch links resume operation after CTP reset. Perform a data 
collection and contact the next level of support. Refer to 
Exit MAP.
5
As indicated by event code 062, Fabric Controller software detected a 
path to another fabric element (director or switch) that traverses more 
than three interswitch links (hops). Fibre Channel frames may persist 
in the fabric longer than timeout values allow.
Advise the customer of the problem and reconfigure the fabric so the 
path between any two fabric elements does not traverse more than 
three hops.