3-92
3
Web – Click Port, Port Configuration or Trunk Configuration. Modify the required 
interface settings, and click Apply.
Figure 3-54   Port - Port Configuration
CLI – Select the interface, and then enter the required settings.
Console(config)#interface ethernet 1/13
Console(config-if)#description RD SW#13
Console(config-if)#shutdown
.
Console(config-if)#no shutdown
Console(config-if)#no negotiation
Console(config-if)#speed-duplex 100half
.
Console(config-if)#negotiation
Console(config-if)#capabilities 100half
Console(config-if)#capabilities 100full
Console(config-if)#exit
Console(config)#interface ethernet 1/21
Console(config-if)#media-type copper-forced
Console(config-if)#