Minicom Advanced Systems 232 IP Manual Do Utilizador

Página de 47
USER GUIDE 
42 
From In the Settings window you can do the following: 
KVM.NET MNG – Press the spacebar to toggle between enabling and disabling 
KVM.net management. When enabled the Smart 216 IP unit is remotely managed 
by Minicom’s KVM.net system.  
KVM.NET ADD – Here you can change the static IP address of the KVM.net 
Manager. 
HOT KEY – By pressing ShiftShift the OSD appears. You can replace Shift
Shift with any of the following: 
  Ctrl, Ctrl 
  Ctrl, F11 
  Print Screen 
Press the Spacebar to toggle between options. To display the OSD in future press 
the new hotkey. 
KEYBOARD LANGUAGE - Press the Spacebar to toggle between the language 
options. It can be changed to French or German. 
28.7 DDC – F10 
Display Data Channel (DDC) is a VESA standard for communication between a 
monitor and a video adapter.  
From the Settings window, input the DDC information of the monitor connected to 
the Smart 216 IP switch into the memories of all connected ROCs when first 
installing system. 
To input the DDC information:  
Press F10. “Please wait” flashes a few times and disappears. The monitor’s DDC 
information is sent to all ROCs. 
28.7.1.1 Updating the DDC information 
Update the DDC information in any of the following circumstances:  
  When replacing the monitor connected to Smart 216 IP Switch 
  When adding a new ROC to the system 
  When reconnecting an existing ROC that was temporarily used in a 
different system 
To update the DDC information, repeat the steps as set out above.