Alcatel Carrier Internetworking Solutions 7700 Manual Do Utilizador

Página de 68
4
Installing the Hardware
March 2005
Items Required
• Grounding wrist strap (included)
• Phillips screwdriver
• Flat-blade screwdriver
• Serial cable
Site Preparation
Environmental Requirements
OmniSwitch 7700/7800 switches have the following environ-
mental and airflow requirements:
• The installation site must maintain a temperature 
between 0° and 45° Celsius (32° and 122° Fahrenheit) and 
not exceed 95 percent maximum humidity (noncondens-
ing) at any time.
• Be sure to allow adequate room for proper air ventila-
tion at the front, back, and sides of the switch. Refer to 
 for minimum clearance 
requirements. No clearance is necessary at the top or 
bottom of the chassis.
Electrical Requirements
OmniSwitch 7700/7800 switches have the following general 
electrical requirements:
• Each switch requires one grounded electrical outlet for 
each power supply installed in the chassis (up to three for 
OS7700 switches; up to four for OS7800 switches). 
OmniSwitch 7700/7800 switches offer both AC and DC 
power supply support. Refer to the Hardware Users Guide 
for more information.
• For switches using AC power connections, each 
supplied AC power cord is 2 meters (approximately 6.5 
feet) long. Do not use extension cords.
Redundant AC Power. If possible, it is recommended 
that each AC outlet resides on a separate circuit. With 
redundant AC, if a single circuit fails, the switch’s remain-
ing power supplies (on separate circuits) will likely be 
unaffected and can therefore continue operating.
• For switches using DC power, refer to the Hardware 
Users Guide for more information, including installation 
guidelines.
Installing the Hardware