Adtran 1200657L2 Manual Do Utilizador

Página de 192
Chapter 6. Diagnostics
61200659L1-1
MX2800 STS-1 User Manual
6-11
Metallic Diagnostics
M
ETALLIC
 D
IAGNOSTIC
 
loopback test loops the entire STS-1 back 
to the local loop side. The end effect of this test is a loopback of all 
VT/Ports after being fully multiplexed and de-multiplexed to and 
from the STS-1 and passed through both directions of the LIU. 
During this test, the incoming STS-1 is disconnected from the 
STS-1 receiver and the outgoing STS-1 signal is substituted in its 
place. See Figure 6-14 for an illustration of this test.
Figure 6-14.  Metallic Diagnostics Loopback Test
STS-1
MAPPER
T1/E1 LIU
(1 of 28)
T1/E1 LIU
(28 of 28)
STS-1
LIU
CODEC
(1 of 28)
CODEC
(28 of 28)