Adtran 1200657L2 Manual Do Utilizador

Página de 192
Chapter 3. Configuration
3-6
MX2800 STS-1 User Manual
61200659L1-1
Network Protection
Enable or disable the unit’s ability to automatically route 
information to the backup STS-1 in the event of a primary STS-1 
failure. With 
N
ETWORK
 P
ROTECTION
 set to 
E
NABLED
, all information 
is automatically routed to the backup STS-1 in the event that the 
primary STS-1 fails. When 
N
ETWORK
 P
ROTECTION
 is set to 
D
ISABLED
, the stand-by controller will be used to protect against 
failures of the circuitry on the active controller.
Max. Switch Threshold
The value entered in this field determines the number of times per 
hour the unit is allowed to switch between controller cards. If the 
cards switch more than the 
M
AX
 S
WITCH
 T
HRESHOLD
 
within one 
hour, the unit issues a trap and stops switching cards for the next 24 
hours. The default setting is 
3
 times an hour.   
Min. Switching Period
After the unit switches controller cards, the number of seconds 
entered in this field must pass before another card switch will be 
allowed. The default setting is 
10
 seconds.
Miscellaneous
Loopback Timeout
Sets the loopback timeout to 
D
ISABLED
MIN
.
MIN
.
10 
MIN
.
15
MIN
.
30 
MIN
.
45 
MIN
. or 
HR
When choosing a setting for 
N
ETWORK
 P
ROTECTION
, there are many 
cabling and network provisioning issues to consider. For configuration 
examples of the different modes of protection, refer to 
Chapter 7, Circuit and Network Redundancy
.