Chapter 7. Circuit and Network Redundancy
7-4
MX2800 STS-1 User Manual
61200659L1-1
Table 7-1.  Configuration Requirements for Circuit Recovery
CIRCUIT AND NETWORK FAILURE RECOVERY MODE
In this mode, two controller cards are installed and connected to 
two individual STS-1 lines. This is, of course, the most complete 
mode of redundancy. In this mode, the primary controller card is 
connected to the primary STS-1 line and the secondary controller 
card is connected to the secondary STS-1 line. The primary card 
and line actively transmit data, while the other card and line stand 
by ready to take over if the first card and line fail. For example, if 
C
ARD
 A
 fails, then control switches to 
C
ARD
 B
 and 
NET B
.
An important feature of the MX2800 STS-1 is its ability to 
internally re-route the network connection if a controller card and 
the opposite network connection fail. For example, in the 
illustration given in Figure 7-3, failed 
NET A 
is connected to 
healthy 
C
ARD
 A
; and healthy 
NET B
 is connected to failed 
C
ARD
 B
Selection Path
Recommended Setting
Config > Network Interface > XCV Threshold
1E-3 (see the following note)
Config > Network Interface > Network Protection
Disabled
Config > Network Interface > Max. Switch Threshold
3
Config > Network Interface > Min. Switching Period
10 seconds
Config > T1/E1 Interface > T1/E1 Circuit Protection
Enable all or select the
T1/E1s that redundant 
switching should occur on.
Config > T1/E1 Interface > XCV Threshold
1E-3 (see the following note)
The XCV Threshold settings are based on the error rates 
considered acceptable on the STS-1 or DS-1 before switching.