Chapter 4. Status
61200659L1-1
MX2800 STS-1 User Manual
4-9
H
OLDOVER
 
– indicates that a failure in the selected clock sourc 
has occurred and the unit has entered hold-over mode. In this 
mode, the last known good clock reference frequency will be 
held within 4.1 ppm for a minimum of 24 hours.
PRI Ext. Clock
The PRI EXT Clock alarms indicate when a failure condition is 
encountered on the PRImary clock source (if configured).  The 
possible values for this alarm are:
D
ISABLED
 
 
indicates that the selected clock has been disabled 
by the user and will not be used.
N
ORMAL
 
 
indicates that the clock source is currently being 
used a the timing reference.
A
VAILABLE
 
 
indicates that the clock source is available to be 
used as a timing source if a failure of the current source occurs.
LOS/AIS 
 
indicates that the clock source is not valid due to an 
LOS or AIS condition.
F
AIL
 
 
indicates that an internal hardware failure on the unit 
prevents the clock source from being used.
U
NAVAILABLE
 
– indicates that the user has specified a T1/E1 
port to be used as an external clock source, but the port has not 
been enabled.
SEC Ext. Clock
The SEC EXT Clock alarms indicate when a failure condition is 
encountered on the SECondary clock source (if configured).  The 
possible values for this alarm are:
D
ISABLED
 
 
indicates that the selected clock has been disabled 
by the user and will not be used.
N
ORMAL
 
 
indicates that the clock source is currently being 
used a the timing reference.
A
VAILABLE
 
 
indicates that the clock source is available to be 
used as a timing source if a failure of the current source occurs.