Adtran 1280050L1 Folheto

Página de 1
TRACER ETHERNET SWITCH MODULE
P/N 1280050L1
For more detailed documentation, visit us online at  
www.adtran.com
Quick Start Guide
Quick Start Guide, 61280050L1-13A, January 2005
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Copyright 
© 2005 ADTRAN, All Rights Reserved
S
PECIFICATIONS
Interface Type:
(4) 10BaseT/100BaseTX interfaces with auto MDI/MDIX 
crossover on all interfaces
Flow Control:
Back-pressure flow control on all half-duplex interfaces
Pause-frame flow control on full-duplex interfaces
Environmental 
Specifications:
Operating Temperature: -25°C to 65°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95% non-condensing
Compliance:
FCC Part 15, Class A
N
ETWORK
 C
ONNECTION
 P
INOUT
Pin
Name
Source
Description
1
RX1
Attached Equipment
Receive Positive
2
RX2
Attached Equipment
Receive Negative
3
TX1
Module
Transmit Positive
4, 5
UNUSED
N/A
6
TX2
Module
Transmit Negative
7, 8
UNUSED
N/A
I
NSTALLATION
 I
NSTRUCTIONS
1.
Remove the cover plate from the appropriate option slot in the TRACER 
rear panel.
2.
Slide the TRACER Ethernet Switch Module into the option slot until the 
module is firmly positioned in the chassis.
3.
Secure the thumbscrews at both edges of the module. Tighten with a 
screwdriver.
4.
Connect the cables to the associated device(s).
5.
Complete installation of remaining modules and system as specified in 
the TRACER 6000 Series System Manual.
The TRACER Ethernet Switch Module is not
hot-swappable. Remove power from the TRACER 
system before installing or removing the module.