Fan speed in revolutions per minute (RPM) (monitored)
Fan Fault LEDs (controlled)
Configuration Rule
The minimum system configuration requires a complete set of two working fan
trays—Fan Tray 0 for the CPUs and Fan Tray 1 for the FC-AL drives and PCI
cards.
Note –
Do not attempt to access any internal components unless you are a qualified
service technician. Detailed service instructions can be found in the Sun Fire V490
Server Parts Installation and Removal Guide
, which is included on the Sun Fire V490
Documentation CD.
About FC-AL Technology
Fibre Channel (FC) is a high-performance serial interconnect standard designed for
bidirectional, point-to-point communication among servers, storage systems,
workstations, switches, and hubs.
Fibre Channel-Arbitrated Loop (FC-AL) is an important enhancement to the FC
standard, developed specifically to meet the needs of storage system interconnects.
Employing a simple loop topology, FC-AL can support both simple configurations
and complex arrangements of hubs, switches, servers, and storage systems.